Install and OpenSees.exe
Download the setup from the Download page and run it. FEA OpenSees Bridge signs in and updates the same way as FEA Studio: sign in with the email address you were invited with.
OpenSees is the only solver. Install OpenSees yourself from opensees.berkeley.edu. The program looks for OpenSees.exe in this order:
- the FEA_OPENSEES environment variable (the exe or its folder);
- the OpenSees.exe you chose with Analysis › OpenSees program… (kept in %LOCALAPPDATA%\FeaStudio\opensees.txt);
- an opensees folder beside the application;
- the PATH;
- OpenSees* folders under Program Files, C:\ and your user folder.
If it isn’t found, the study stops with a message saying so: choose OpenSees.exe with Analysis › OpenSees program… › Browse…, which also shows the version found. The integration was tested with OpenSees 3.8.0.
Each OpenSees run uses one thread for its maths library. Set FEA_OPENSEES_THREADS to change that, and FEA_OPENSEES_PARALLEL to change how many runs go at once.
Licence notice
OpenSees is not part of this product. The program writes the model as an OpenSees input script and runs the OpenSees.exe that you installed. It doesn’t include, install or download OpenSees.
OpenSees is distributed by the Regents of the University of California under its own licence. It is free for educational, research and non-profit use. Commercial use, and redistribution, may need a licence from UC Berkeley (Office of Technology Licensing). You are responsible for holding the licence that applies to your use.
The first time you run OpenSees on a computer, a notice says this. Choose I understand to go on; it isn’t asked again. Cancel stops the run.
Bridge templates
Choose File › New… (Ctrl+N), set the region, units and design codes, and pick a template. The templates are also in File › Samples under Templates. Each one makes members, supports, load cases and studies.
| Family | Template | What it makes |
|---|---|---|
| Girder | Bridge superstructure | Deck, girders, diaphragms and bearings only: the span on fixed seats |
| Single-span overpass | One span between closed-wall abutments: girders, deck, bearings, wing walls, approach slabs | |
| Multi-span overpass | Girder spans over single-column piers with haunched caps on pile caps | |
| Waterway crossing | Six spans over a river on single-column piers and pile foundations | |
| Straight flyover | A long viaduct over a crest curve on single-column piers | |
| S-curve flyover | A viaduct on reverse curves over a crest | |
| U-turn flyover | A viaduct turning through 180° on a circular curve | |
| 270° ramp | A three-quarter-turn ramp rising along a circular curve | |
| Plate girder bridge | Continuous steel I-girders, concrete slab, cross-frames; skew and plan curvature | |
| Box | Box girder bridge | Continuous concrete or composite box of shell plates, one or two cells |
| Truss | Truss bridge | Pratt, Howe or Warren; through or deck; floor beams, stringers and bracing |
| Arch | Tied arch bridge | Parabolic ribs and tie girders; vertical or network hangers; wind bracing |
| Cable-stayed | Cable-stayed bridge | One or two H, A or single pylons; fan, harp or semi-fan stays |
| Suspension | Suspension footbridge | Parabolic main cables, portal towers, backstays and a stiffened deck |
The eight girder bridges are built as LOD300 BIM models (IFC 4.3) and converted to the analysis model. Only they have components and an alignment, and only their piers are recognised by the bridge pushover.
Main parameters of the other templates
| Template | Geometry | Members and supports |
|---|---|---|
| Plate girder bridge | Spans (default 30, 40, 30 m), girders, girder spacing, deck overhang, skew, plan radius, cross-frame spacing | X or V (K) cross-frames, girder section, depth over piers and haunch length, angles, support diaphragms, web stiffeners, slab thickness, fixed support line |
| Box girder bridge | Spans (default 40, 55, 40 m), one or two cells, box depth, deck width, cantilevers, depth over piers, vertical or inclined webs | Concrete or steel + slab; flange, web and diaphragm thicknesses; fixed support line |
| Truss bridge | Truss type, through or deck, span, number of spans, panels, truss depth, truss spacing, stringers, inclined end posts | Rigid or pinned web joints; chord, vertical, diagonal, floor beam, stringer and bracing sections; fixed + sliding or pinned bearings |
| Tied arch bridge | Span, rise / span, rib spacing, rib inclination, panels, vertical or network hangers, clearance, wind bracing, slab or load panels | Arch rib, tie, floor beam, hanger, strut and brace sections; hanger element Cable or Truss; fixed + sliding or pinned bearings |
| Cable-stayed bridge | One or two pylons, main and back spans, auxiliary piers, girder and cable spacing, pylon shape, cable layout, pylon height above and below the deck | Edge girders, cross beams, pylon material and sections, stay cables |
| Suspension footbridge | Span, sag / span, deck width, cable plane offset, hanger spacing, shortest hanger, tower below deck, backstay length | Cable element Cable or Truss; main cable, hanger, girder, cross beam, bracing and tower sections; fixed or pinned tower feet |
Every template has load parameters (surfacing or deck dead load, lane or crowd load, wind where offered) and a number of modes.
Girder bridge parameters
The eight girder bridges share these parameters. Some show only for certain choices.
| Group | Parameter | Default | Notes |
|---|---|---|---|
| Geometry | Spans | by template | Span lengths along the alignment, e.g. “4*30”; 8–80 m, up to 40 spans |
| Geometry | Bridge start station | 0 m | Station of the start abutment |
| Geometry | Curve radius | 0 | Curved templates; 0 takes it from the spans |
| Geometry | Deck height | by template | Deck top over the ground at the start abutment |
| Geometry | Crest rise / Ramp rise | by template | Templates with a crest or ramp profile |
| Geometry | Skew | 0° | −45° to 45°, from square to the alignment |
| Geometry | Deck width | 12 m | 4–40 m |
| Geometry | Cross-fall | 0 % | Crown: both sides fall away from the axis |
| Members | Superstructure | PSC girders | PSC girders, RC beams, steel plate girders, concrete box girder, solid slab |
| Members | Girder section | AASHTO BT-63 | 92 AASHTO, Caltrans and WSDOT sections |
| Members | Girders | 5 | 2–12 |
| Members | Girder spacing | 0 | 0 spreads the girders over 85 % of the deck width |
| Members | Girders on tight curves | Draw in under the deck | Or keep the spacing |
| Members | Continuity | Simple spans | Or continuous |
| Members | Diaphragms per span | 3 | Intermediate diaphragms, evenly spaced |
| Members | End and pier diaphragms | Off | Diaphragms over the bearings too |
| Members | Slab thickness | 350 mm | |
| Members | Barriers | On | |
| Members | Bent type | by template | Single column, multiple column, wall column, multiple pile, box girder (flared column) |
| Members | Columns per pier | 2 | Multiple column and multiple pile bents |
| Members | Column size | 1500 mm | Diameter |
| Members | Cap depth | 1400 mm | |
| Supports | Foundations | by template | Isolated footing, combined footing, pier pile, pile shaft (belled), pile group, combined pile group |
| Supports | Pile length | 18 m | |
| Supports | Abutment piles | Off | |
| Supports | Bearings | Pot (fixed/guided/free) | Or elastomeric |
| Loads | Surfacing | 50 mm | |
| Loads | Lanes | 2 | |
| Loads | Lane load | 9.3 kN/m | Per lane (AASHTO HL-93: 9.3 kN/m over 3 m) |
| Analysis | Modes | 12 |
The load cases are self-weight, surfacing and barriers, and the lane load.
Alignment
On a girder bridge, Edit alignment… at the top of the Template panel opens three tables. Until you edit them, they follow the template’s layout.
| Table | Columns |
|---|---|
| Horizontal alignment | Type (line, curve, spiral), length, radius and turn for curves; from station 0 |
| Vertical profile (PVIs) | Station, elevation, vertical curve length; parabolic vertical curves |
| Cross-fall by station (superelevation) | Station, left slope, right slope (% away from the axis, negative falling); linear between stations |
- Import LandXML… reads the horizontal and vertical alignment, and superelevation, of a LandXML 1.2 file (Civil 3D, OpenRoads, 12d).
- Use the layout goes back to the alignment the template makes from the spans, radius, rise and cross-fall.
- With your own profile, Ground level replaces Deck height.
Components
On the eight girder bridges, click a part in the 3D view to edit it in the Template panel. Each property follows its template parameter until you change it. Changes apply to chooses the scope.
| Component | Properties | Scopes |
|---|---|---|
| Girder | Girder section from the library and its dimensions; end blocks; for steel plate girders the depth, flange widths and thicknesses and web thickness | This girder · Gn in every span · every girder of a span · every exterior or interior girder · every girder |
| Diaphragm | Present, thickness, depth (0: from the girders) | This diaphragm · intermediate ones of a span · every diaphragm on a support · every one of its type · every diaphragm |
| Bearing | Type (from the layout, pot fixed, pot guided along, pot guided across, pot free, elastomeric), plan size, height | This bearing · every bearing on a support · every bearing of a line · every bearing |
| Pier | Skew, bent type, columns, wall thickness; cap depth D1, end depth DE, taper L1, width B1, overhang; column shape and dimensions; foundation kind, footing or pile cap size, piles, bell | This pier · every pier |
| Abutment | Skew, wall thickness; footing; back wall; wing wall; approach slab; piles | This abutment · both abutments |
Column shapes: circular, rectangular, tapered circular, tapered rectangular, flared circular, flared rectangular and Y-shaped.
- The most specific change wins. A change for a broader scope removes the same property from narrower changes inside it.
- Copy the changes of this … to gives one component’s changes to a broader scope.
- Select them selects the scope in the 3D view. Reset to template removes the changes of the scope. Reset all removes every component change.
- Clicking a pier column picks the whole pier: cap, columns, footings and piles.
- A pier’s or abutment’s skew is the skew of its support line.
Materials and sections
Linear analyses use the elastic members, shells and links of the analysis model. The seismic studies replace the pier columns with fibre sections:
| Part | In the bridge pushover and time history |
|---|---|
| Pier columns | RC fibre sections, circular or rectangular from the column profile; other shapes as a circle of equal area |
| Bars | From the column design if one covers the column; else ρl (default 1.5 %, 32 mm bars) and ρs (default 0.8 %, 16 mm spirals or hoops) |
| Concrete | Mander confined core and cover (Concrete04), no tension; cover spalling at 0.005 |
| Steel | Steel02 with hardening to fue = 1.4 fy; reduced ultimate strain εsu,R 0.09 (≤ 32 mm bars), 0.06 above |
| Expected strengths | f′ce = 1.3 f′c, fye = 1.13 fy (option, on by default) |
| Plastic hinges | HingeRadau at the base, and at the top of multi-column bents; Lp = 0.08 L + 0.022 fye dbl ≥ 0.044 fye dbl (SI) |
| Bent caps | Elastic, 0.75 Ig and 0.2 J |
| Superstructure | Uncracked |
| Wall piers (shells) | Elastic |
Define › OpenSees library… lists the OpenSees materials and elements the program writes, what each models and whether this model uses it.
Bearings and links
In the seismic studies, the converter’s bearing bars are replaced by one link per bearing, from the bottom to the top (x up, y along the bridge).
- Held directions keep the bars’ stiffness.
- Elastomeric pads use their elastic stiffness.
- Pot bearings slide in their free directions: elastic–perfectly plastic friction μ W, sticking up to 2 mm. W is the tributary weight per bearing; μ is Bearing friction μ (default 0.04).
Abutments
The study property Abutments has two choices.
- Backfill and shear keys (default): at each deck node over the abutment, a hyperbolic backfill spring behind the back wall acts after the Expansion gap (default 25 mm), in compression only. Across the bridge, shear keys at the middle node are elastic–plastic with a gap, of strength Shear key strength × the abutment dead load (default 0.3).
- Fixed seats: the bearings sit on fixed seats.
The backfill stiffness and strength are the Caltrans values, scaled by the wall height and width. Foundations are fixed, or Springs: a Gazetas surface footing of the pile cap or footing size on soil of the study shear modulus. Piles are not counted.
Analysis types
Every study runs on OpenSees. The Analysis menu lists them in this order. Run analysis (F5) runs the study selected in the Explorer.
| Command | What it does |
|---|---|
| Linear static | One linear solve per load case or combination |
| Modal | Natural periods, mode shapes and mass participation |
| Linear dynamic | Linear time history (Newmark average acceleration): loads, force histories or a ground motion |
| Nonlinear static | Large-displacement static analysis in load increments |
| Response spectrum | Modal combination (CQC or SRSS) of a design spectrum |
| Bridge pushover | Pushes the bridge, then each bent along and across; checks capacity against demand |
| Bridge time history | Nonlinear time history of the bridge, optionally with multi-support excitation |
You can also add a study in the Explorer: right-click the Analysis stage and choose Add study. In this product a pushover or time history study is always a bridge study. There is no building pushover, IDA or progressive collapse.
The study property group Bridge seismic:
| Property | Default | Notes |
|---|---|---|
| Direction | Along the bridge | Whole-bridge push or shaking; bent pushovers run both ways |
| Code | AASHTO Guide Spec | Or Caltrans SDC 1.7 |
| PGA coefficient As (g) | 0.4 × SDS | The spectrum at T = 0 |
| Column steel ratio ρl (%) | 1.5 | Columns without a design |
| Spiral or hoop ratio ρs (%) | 0.8 | Confinement and core εcu |
| Expected strengths | On | f′ce = 1.3 f′c, fye = 1.13 fy |
| Abutments | Backfill and shear keys | Or fixed seats |
| Expansion gap (mm) | 25 | |
| Shear key strength (× dead load) | 0.3 | 0: none |
| Bearing friction μ | 0.04 | |
| Foundations | Fixed | Or springs |
| Multi-support excitation | Off | Time history only |
| Apparent wave velocity (m/s) | 0 | Time history only; 0: no delay |
Bridge pushover
Analysis › Bridge pushover runs the bridge pushover study, or makes one first: uniform pattern, 4 % target drift, 80 steps, hazard SDS 1.0 g, SD1 0.6 g, TL 8 s.
The program finds the parts from the names and groups the girder bridge templates write: pier columns, pier caps and bearings. Without them, vertical members standing on supports are taken as columns. If no piers are found, the command says so.
- The whole bridge is pushed along the study direction.
- From that model, each column’s gravity axial force is taken.
- For each bent and direction: the column’s moment–curvature at that force, first yield where a bar reaches εy, and the ultimate curvature where the core reaches εcu or a bar εsu,R.
- The bent alone is pushed at the bearing seat, with P-Δ. Its capacity is where a hinge section first reaches a strain limit, or where the strength falls to 80 %.
Up to four bent runs go at once.
Time history and multi-support excitation
Add records first, from the Assign menu:
- Import ground motion…: a PEER NGA .AT2 file or text columns;
- Import ground motion pair…: two horizontal components, the first along the study direction;
- Generate ground motion…: an artificial record matched to the ASCE 7 design spectrum (SDS, SD1, TL, duration, seed, number of records, components).
Analysis › Bridge time history makes a study that takes over the records, and runs it. The bridge is shaken along its own axis (first support to last) or square to it.
Multi-support excitation
- The record is integrated to velocity and displacement, with a baseline correction so the ground ends at rest.
- The displacement is imposed at every support: column bases, abutment seats and spring ground nodes. With an apparent wave velocity, each support’s record is delayed by its station along the bridge divided by that velocity.
- Second horizontal and vertical components are imposed too when the bridge shakes along a global axis.
- Displacements are absolute, and the Rayleigh damping is stiffness-proportional only.
- Roof and seat displacements, drifts and hinge curvatures are reported relative to the ground. 3D frames and the displacement envelope stay absolute.
Base shear, in every bridge time history, is the sum of the forces in the elements at the supports, along and across the shaking.
Capacity checks (AASHTO / Caltrans)
Results › Bridge capacity check lists every bent and direction in the Output panel.
- Capacity Δc: the bent pushover’s first strain limit; by hand Δy + θp (L − Lp/2), θp = Lp (φu − φy), from the idealised moment–curvature (Mp by equal area).
- Demand ΔD: T = 2π √(W / (g K)), Sa from the AASHTO design spectrum, ΔD = Rd Sa g (T/2π)², Rd = (1 − 1/μD) T*/T + 1/μD, T* = 1.25 Ts. After a time history, the bent’s peak seat displacement relative to its base.
| Check | AASHTO Guide Spec | Caltrans SDC 1.7 |
|---|---|---|
| Displacement | ΔD ≤ Δc | ΔD ≤ Δc |
| μD, single-column bent | ≤ 5 | ≤ 4 |
| μD, multi-column bent | ≤ 6 | ≤ 5 |
| μc | — | ≥ 3 |
| P-Δ: Pdl ΔD | ≤ 0.25 Mp | ≤ 0.20 Mp |
| f′ce | 1.3 f′c | max(1.3 f′c, 5 ksi) |
Status of the code values
Caltrans: μD, μc, εsu,R, fye, f′ce and the P-Δ limit were checked against SDC 1.7. Its plastic hinge length, backfill and shear key values were not. SDC 2.0 and later changed some of these rules. The AASHTO Guide Spec values have not been checked against the published document. The program prints this status with every check and in the report.
Results and report
- Results › Seismic charts: Bent pushover (with the idealisation, Δc, hand Δc and ΔD), Column moment–curvature, and Bridge capacity and demand (displacements, or ductility against the limit). Charts open as tabs in the main area.
- In the 3D view, a ring at each column base: green within the limits, amber past 80 % of one, red failing.
- Results › OpenSees outputs and OpenSees log show what OpenSees returned. Export OpenSees model writes the model as an OpenSees script.
- Results › Bridge seismic report, also under Reports in the Explorer: the bridge studies chapter by chapter, with the design spectrum, a summary table and a section per bent and direction. Save it as PDF, Word or HTML.
Design
After a linear static analysis, Design › Design… designs the model in one go. FEA OpenSees Bridge has these design modules from FEA Studio:
- RC beams and columns, including pier column stacks; designed column bars are used by the bridge pushover and time history;
- steel members;
- footings;
- connections, by hand checks.
For the design codes, see Design codes. Slabs, walls and composite floors are not in this product.
Drawings and IFC
- Drawings: reinforcement and steel shop drawings from the designed model, in the Explorer’s Drawings stage.
- File › Import IFC and File › Import Revit model make a structural model from a BIM model.
- File › Export results to IFC writes forces, verdicts and reinforcement into a copy of the original IFC file.
Verification
Checked with OpenSees 3.8.0:
| Case | OpenSees | Reference |
|---|---|---|
| Single-column bent, D 1.5 m, P 8.5 MN, 8.4 m to the seat: first yield | 66.5 mm | 66.7 mm by φ′y/(3L)(L³ − e³) |
| Same bent: displacement capacity | 455 mm | 434 mm by hand, Δy + Δp (within 5 %) |
| Multi-span overpass shaken across, multi-support with no delay against uniform: roof | 22.6 mm | 22.3 mm |
| Same: bent seat | 16.5 mm | 16.1 mm |
| Same: base shear | 8.15 MN | 7.96 MN |
Limitations
- OpenSees is not included. You need your own OpenSees.exe and the licence that applies to your use.
- The bridge pushover and time history find piers on the girder bridge templates, or on models whose pier columns are in a “Columns” group. The truss, arch, cable-stayed and suspension templates have no recognised piers.
- Wall piers made of shells stay elastic in the seismic studies.
- Pile foundations are not modelled as springs; the spring option uses a surface footing.
- The stays, main cables and hangers of the templates are straight axial bars, without pretension, sag or slackening.
- The AASHTO Guide Spec values, and some Caltrans values, are not yet verified (see Capacity checks).
- Artificial ground motions are not real earthquakes. Use real records for design decisions.
- There are no building templates, slabs, walls, composite floors, demolition, building pushover, IDA or collapse in this product. They are in FEA OpenSees Building and FEA Studio.